Description
- For evaluating measuring bridges (e.g. strain gauge load cells)
- 2 strain gauge inputs (16 bits)
- Measurement range 10 mV/V

Analog Inputs |
|
| Type | strain gauge |
| Number | 2 |
| Resolution | 16 bits |
| Measurement range | 10 mV/V |
| Measurement precision | typically ±0.0565 % |
| Conversion time per channel | ≤ 25 µs |
| Hardware filter | 8 kHz (-3dB), -60 dB/decade |
| Galvanic isolation | Yes |
| Bridge supply voltage | 3,333 V DC |
| Min. Bridge resistance | 100-5000 Ω |
Mechanical Features |
|
| Dimensions | 42.2 x 27 x 91.3 mm (W x H x D) |
Article Number/Certification |
|
| Article number | 18-001-282 |
Reviews