Description
-
- 2 analog strain gauge inputs (24 bits)
- For evaluating measuring bridges (e.g. strain gauge load cells)
For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.

For the S-DIAS system, EPLAN Macros are available for simple integration into the control cabinet.
Analog Inputs |
|
| Type | strain gauge |
| Number | 2 |
| Resolution | 24 bits |
| Measurement range | ±1.875 mV … ±120 mV |
| Measurement precision | ±0.0031 % noise with filter word 2
±0.001 % / °C temperature drift |
| Sensor break detection | Yes |
| Bridge supply voltage | +5 V DC |
| Load cell rated values | 0.25-16 mV/V |
| Maximum load/channel | 75-5000 Ω (when using one channel) / 150-5000 Ω (when using both channels) |
Mechanical Features |
|
| Dimensions | 12.5 x 104 x 72 mm (W x H x D) |
| Protection type | IP20 |
Article Number/Certification |
|
| Article number | 20-009-022 |
| Standardization/certification | UL 508 (E247993) |